Slab floor

FISinter (to initial point) Federative information system of producers on products and services
FISinter
Code Page utf-8
 Alongside with placing information about their goods and services on the FISinter, producers obtain registered unique identification of their goods and services to be used in the flow of documents composed by their counterparts.
      Description of goods/services - Slab floor, is given under the below mentioned section of the FISinter.
      Enter the section and learn detailed description of the available trademarks and modifications of the goods/services - Slab floor.
  •   Building materials, structures, buildings and installations
    • Slab floor 1.141-1 V15
      Rocket control system series 5151-80, series 1. 141-1 from class concrete in fastness on compression Â15
    • Slab floor KP V22,5F75
      Collector. From class concrete on compression strength of Â22, 5, marks on freezing resistance of F75
    • Slab floor KPD V15
      Continuous
    • Slab floor KPD V25F200
      Continuous
    • Slab floor NTO V20F50
      Prestressed from heavy cement concrete of class in fastness on Â20 compression, marks on freezing resistance of F50
    • Slab floor NTV V20F50
      Prestressed from heavy cement concrete of class in fastness on Â20 compression, marks on freezing resistance of F50
    • Slab floor NV V20F50 prednp
      Prestressed from heavy cement concrete of class in fastness on Â20 compression, marks on freezing resistance of F50
    • Slab floor NV V20F50 on
      With conventional reinforcement from heavy cement concrete of class on compression strength of Â20, marks on freezing resistance of F50
    • Slab floor PP 2TV30F5
      Reinforced concrete type "double t" from class concrete in fastness on Â30 compression of mark on freezing resistance of F50
    • Slab floor PP 4P6,0kPa
      With conventional reinforcement of type of 4Ï under settlement load on overlap 6, 0 kPa from heavy cement concrete of class on compression strength Â15, marks on freezing resistance of F50, marks on watertight of W2
    • Slab floor PP 5g-3n V22,5F50
      Cïëîøíàÿ with conventional reinforcement of type of 5ï-3ò from heavy cement class concrete on compression strength of Â22, 5, freezing resistance of F50
    • Slab floor PP PB V15F50
      Planar from class concrete on compression strength of Â15, marks on freezing resistance of F50
    • Slab floor PP RB V15F50
      Finned from class concrete on compression strength of Â15, marks on freezing resistance of F50
    • Slab floor PP UNT V20
      Prestressed from heavy cement concrete of class in fastness on Â20 compression, freezing resistance of F50
    • Slab floor PP UNU V20
      Prestressed from heavy cement concrete of class in fastness on Â20 compression, freezing resistance of F50
    • Slab floor PP V15
      With conventional reinforcement from heavy cement concrete for channels class on compression strength of Â15, marks on freezing resistance of F100 , marks on watertight of W6
    • Slab floor PP V15 zhb
      Reinforced concrete multi-void prestressed from heavy cement concrete of class on compression strength of Â15, marks on freezing resistance of F200
    • Slab floor PP V15/2
      Reinforced concrete multi-void prestressed from class concrete on compression strength Â15
    • Slab floor PP V20
      With conventional reinforcement from heavy cement concrete class on compression strength of Â20, freezing resistance of F75 for houses 101 and 111 series
    • Slab floor PP V20 zhb
      Reinforced concrete finned for building overlaps of different allotment with conventional reinforcement from class concrete on compression strength of Â20 mark on freezing resistance of F50
    • Slab floor PP V22,5
      With conventional reinforcement from heavy cement concrete of class on compression strength of Â22 5
    • Slab floor PP V22,5 zhb
      Reinforced concrete continuous for overlaps of dwelling building from class concrete on compression strength of Â22, 5 marks on freezing resistance of F50
    • Slab floor PP V22,5F50
      Reinforced concrete finned from class concrete on compression strength in 22, 5, marks on freezing resistance of F50
    • Slab floor PP V22,5F50 spl
      Continuous prestressed pension fund type from heavy cement concrete of class on compression strength of Â22, 5, freezing resistance of F50
    • Slab floor PP V22,5F50 zhb
      Reinforced concrete. Assembled the coverages of channel and camera of drain and sewerage networks from class concrete on compression strength of Â22, 5, marks on freezing resistance of F75, marks on watertight of W4
    • Slab floor PPB V22,5F50
      Concrete class in 22, 5, freezing resistance f 50
    • Slab floor PPKTZH
      Reinforced concrete for overlaps of íåïðîõîäíûõ pipe ducts with conventional reinforcement from heavy cement concrete of class on compression strength of Â15, marks on freezing resistance of F50
    • Slab floor PPMV20
      Multi-void with conventional reinforcement from heavy cement concrete class on compression strength of Â20, marks on freezing resistance of F50
    • Slab floor PPMZH V15
      Multi-void prestressed from class concrete on compression strength Â15
    • Slab floor PPP TP
      Basements with conventional reinforcement from heavy cement concrete of type "technological process", of class on compression strength of Â20, marks on freezing resistance of F50
    • Slab floor PPRZH
      Reinforced concrete finned for overlaps and compensations of buildings of different appointment from class concrete on compression strength of Â22, 5, marks on freezing resistance of F50
    • Slab floor PPRZH zhb
      Reinforced concrete finned for overlaps and compensations of buildings of different appointment from class concrete on compression strength of Â27, 5, marks on freezing resistance of F50
    • Slab floor PPS P V22,
      Continuous with conventional reinforcement from heavy cement concrete of class On compression strength of Â22, 5, brands on cold resistance of F50
    • Slab floor PPSZH V22,5
      Reinforced concrete continuous for large-panels building from class concrete on compression strength of Â22, 5, freezing resistance of F50
    • Slab floor PPSZH V15F50
      Reinforced concrete continuous from class concrete on compression strength of Â15, marks on freezing resistance of F50
    • Slab floor PPSZH V20
      Reinforced concrete continuous with conventional reinforcement from class concrete on compression strength of Â20, marks on freezing resistance of F50
    • Slab floor PPSZH V20 spl
      Reinforced concrete continuous for large-panels building from class concrete on compression strength of Â20; marks on freezing resistance of F50
    • Slab floor PPSZH V20 zhb
      Reinforced concrete continuous for large-panels building from class concrete on compression strength of Â20; marks on freezing resistance of F150; watertight of W4
    • Slab floor PPSZH V20F50
      Reinforced concrete continuous from class concrete on compression strength of Â20, marks on freezing resistance of F50
    • Slab floor PPSZH V22,5
      Reinforced concrete continuous for overlaps of dwelling and public building class on compression strength of Â22, 5, marks on freezing resistance of F100
    • Slab floor PPSZH V22,5 zhb
      Reinforced concrete continuous from class concrete on compression strength Â22, 5, marks on freezing resistance of F50
    • Slab floor PPSZH V22,5 zhb sp
      Reinforced concrete continuous p type from class concrete in fastness on compression in 22, 5, marks on freezing resistance of F50
    • Slab floor PPZH V15
      Reinforced concrete prestressed multi-void from class concrete on compression strength of Â15, marks on freezing resistance of F150, marks on watertight of W4
    • Slab floor PPZH V15 zhbtr
      Reinforced concrete for overlaps of íåïðîõîäíûõ pipe ducts from class concrete on compression strength of Â15, marks on freezing resistance F100
    • Slab floor PPZH V15 zhb
      Reinforced concrete continuous for overlaps of dwelling building from class concrete on compression strength of Â15, marks on freezing resistance of F50
    • Slab floor PPZH V20F75
      From class concrete on compression strength of Â20, marks on freezing resistance F75
    • Slab floor PPZH V22,5F50
      Continuous with conventional reinforcement of pension fund type from heavy cement concrete class on compression strength of Â22, 5, freezing resistance of F50
    • Slab floor PPZH V25
      Reinforced concrete ïðåäíàïððÿæåííàÿ multi-void from class concrete on compression strength of Â25, marks on freezing resistance of F150, marks on watertight of W4
    • Slab floor RS 5151-80 V15
      Rocket control system series 5151-80, series 1. 141-1 from class concrete in fastness on compression Â15
    • Slab floor RS 5162-89 V22,5
      Rocket control system series 5162-89 from class concrete on compression strength of Â22 5
    • Slab floor UNT 20F50
      With conventional reinforcement from heavy cement concrete of class on compression strength of Â20, marks on freezing resistance of F50
    • Slab floor UNT V20F50
      Prestressed from heavy cement concrete of class in fastness on Â20 compression, marks on freezing resistance of F50
    • Slab floor UNU V20F50
      With conventional reinforcement from heavy cement concrete of class on compression strength of Â20, marks on freezing resistance of F50
    • Slab floor UNU V20F50 prnpr
      Prestressed from heavy cement concrete of class in fastness on Â20 compression, marks on freezing resistance of F50

20-04-2024