Elektrotechnik- und Kabelerzeugnisse und -Ausr'stungen

Relais elektromagnetisches RPS 15

 
Das Land: Russia
 
 Der Lieferantentyp: Warenhersteller  
 Die Information über den Lieferanten  ProduktionsIdentifizierer

Die Erklärung/Inhaltsangabe:

Three-position, single-shot, with closure and break contact mi. For commutation of electric DC circuits.

Die ausführliche Beschreibung der Marke:

Switches the currents from 0, 01 to 0, 2 and on tension 24-36 V. the maximal number of operation 4õ1000000. clearances 41, 5õ44õ96 of MM. mass on more than 250,. onposition of relay - any. relay the electric parameters in conditions of âîçäåéñò âèÿ work and keep: vibrations of attaching points in the range of frequencies 20-80 Hz upon acceleration to 4g; permanently acting the linear accelerations to 20g; environment temperatures from minus 60 to plus 70 degrees on celsius; atmosphere pressure from 666 to 104000 p (from 5 to 780 MM of mercurial column); relative air humidity to 98% at a temperature of plus 40 hailstones owls on celsius during 48 hrs.. Repeat staying in these conditions shall be allowed after relay exposition in standard climatic conditions not less 12 hrs.. relay are opposed to destructive effect and keep its electric the parameters within limits after action: vibrations of attaching points in the range of frequencies 20-80 Hz upon acceleration to 4g; to 10000 multiple hits with acceleration to 4g; three-time cyclic effect of temperature limits. insulation resistance between current leading by elements and body and inter yes by individual òîêîâåæóùèìè elements, m, no less than: in standard climatic conditions - 100; in conditions excess of moisture - 10; in case of maximum temperature (coils is charged at or current) - 100 the test voltage (the effective value), in: between current leading by elements and chassis earth between coils and contact mi, between coils: in standard climatic conditions - 500; in conditions excess of moisture - 300; at atmospheric pressure 666 p ( 5 MM of mercury column) - 250. between contacts: in standard climatic conditions - 300; in conditions excess of moisture - 180; at atmospheric pressure 666 p (5 MM of mercury column) - 200.

Die Bedingung der Lieferung:

Preis: der Vertragspreis für itm