Sistema federal de información sobre mercancías y servicios (al inicio)
Code Page utf-8
Sistema federativo sobre mercancías y servicios
FISinter

Архив подсистемы «Информация производителей продукции»

Selección de idioma
Búsqueda de información
Detalles
Настройки браузера
Подсистема

Artículos y maquinaria electrotécnica y de cables

Relé electromagnético RES 81 - RES 84


Para esta marca hay versiones - escójalas abajo después de familiarizarse con el resumen y descripció detallada

Aclaración/resumen:

Small-sized, reed switch. Two-position, single-shot. For êîììó òàöèè of electric circuits of direct and alternating current by the frequency to 100 kHz.

Descripción completa de la marca:

Switches the currents from 1õ0, 000001 to 0, 35 and on tension 0, 001-60 V . the environment temperature from - 60 to +70 degree Celsiuses. atmosphere pressure from 200 to 1520 MM of mercury column. relative air humidity at temperature up to 35 degrees on target! ñèþ - not more 98%. vibration-proof and vibration proofness in case of anchorage within a range of frequencies from 5 to 600 Hz - with acceleration to 10g. shock-stability - upon acceleration not more 40g - 10000 hits. impact strength: single hits - 9 hits with acceleration to 20g in case of pulse duration 20-50 incineration facility or to 75g in case of pulse duration 1- 3 incineration facilities; multiple hits - 10000 hits with acceleration to 40g. permanently acting the linear loads - to 10g. relative air humidity to 98% at a temperature of plus 40 hailstones owls on celsius during 48 hrs.. Repeat staying in these conditions shall be allowed after relay exposition in standard climatic conditions not less 12 hrs.. insulation resistance between current leading by elements and body and inter yes by individual òîêîâåæóùèìè elements, m: in standard climatic conditions - 5000; in conditions excess of moisture - 5; in case of maximum temperature (after coil exposition under working íàïðÿ æåíèåì) - 20; test voltage (effective value) between current leading ýëå cops, leading by elements and chassis earth in: in standard climatic conditions - 500; in conditions excess of moisture - 300; resistance of contact circuit on tension 6+/-1 in and current 10+/-1 mitotic activity - not more 0, 25 Omaghs in the process of delivery.

  Versiones/????????????
No.Marcación de la versión
Inter
Nac.
Execution supply voltage of direct current source, in coil designation and connecting method operate voltage, in, not more the drop-away voltage, in, no less than the coils Ñîïðòèâëåíèå, the Omagh the working voltage, in the mass, year, not more the number of sealed-contact reed relays and diodes, pieces the overall dimensions, the MM
1 RES 81
RES 81
ÐÑ4. 569. 790 2, 4; 5; 10; 12, 6; 27; 36 À-Á 1. 3 0. 16 130+/-13 2. 4+/-0. 24 30 1 sealed-contact reed relay of ÌÊÀ-27101 of 44õ16õ22
2 RES 81/1
RES 81/1
ÐÑ4. 569. 790-01 2, 4; 5; 10; 12, 6; 27; 36 À-Á 2. 3 0. 25 345+/-52 5+0. 5/-1. 4 30 1 sealed-contact reed relay of ÌÊÀ-27101 of 44õ16õ22
3 RES 81/2
RES 81/2
ÐÑ4. 569. 790-02 2, 4; 5; 10; 12, 6; 27; 36 À-Á 4. 5 0. 5 1200+/-180 12. 6+1. 3/-5. 4 30 1 sealed-contact reed relay of ÌÊÀ-27101 of 44õ16õ22
4 RES 81/3
RES 81/3
ÐÑ4. 569. 790-03 2, 4; 5; 10; 12, 6; 27; 36 À-Á 9. 0 0. 9 3800+/-760 27+3. 0/-11. 0 30 1 sealed-contact reed relay of ÌÊÀ-27101 of 44õ16õ22
5 RES 81/4
RES 81/4
ÐÑ4. 569. 790-04 2, 4; 5; 10; 12, 6; 27; 36 À-Á 19. 0 1. 9 12500+/-2500 36+/-4 30 1 sealed-contact reed relay of ÌÊÀ-27101 of 44õ16õ22
6 RES 81/5
RES 81/5
ÐÑ4. 569. 790-05 2, 4; 5; 10; 12, 6; 27; 36 À-Á, Â-Ã 4. 8 0. 55 540+/-81 10+1. 0/-2. 0 30 1 sealed-contact reed relay of ÌÊÀ-27101 of 44õ16õ22
7 RES 83
RES 83
ÐÑ4. 569. 792-04 5; 12, 6; 15; 20; 27 Â-Ã 10 0. 8 520+/-78 20+2/-4 45 4 sealed-contact reed relays of ÌÊÀ-27101 of 44õ20õ26
8 RES 84
RES 84
ÐÑ4. 569. 793-03 5; 12, 6; 27; 36 Â-Ã 21. 5 1. 3 5400+/-900 36+/-4 55 6 sealed-contact reed relays of ÌÊÀ-27101 of 44õ24õ26
9 RES 82
RES 82
ÐÑ4. 569. 791 4; 5; 6, 3; 12, 6; 27 À-Á 1. 9 0. 19 175+/-18 4+/-0. 4 35 2 sealed-contact reed relays of ÌÊÀ-27101 of 44õ20õ22
10 RES 82/1
RES 82/1
ÐÑ4. 569. 791-01 4; 5; 6, 3; 12, 6; 27 À-Á 2. 5 0. 26 320+/-32 5+0. 5/-1. 4 35 2 sealed-contact reed relays of ÌÊÀ-27101 of 44õ20õ22
11 RES 82/2
RES 82/2
ÐÑ4. 569. 791-02 4; 5; 6, 3; 12, 6; 27 À-Á 3. 3 0. 3 200+/-30 6. 3+/-1 35 2 sealed-contact reed relays of ÌÊÀ-27101 of 44õ20õ22
12 RES 82/3
RES 82/3
ÐÑ4. 569. 791-03 4; 5; 6, 3; 12, 6; 27 À-Á 6. 5 0. 6 1600+/-240 12. 6+/-1. 3 35 2 sealed-contact reed relays of ÌÊÀ-27101 of 44õ20õ22
13 RES 82/4
RES 82/4
ÐÑ4. 569. 791-04 4; 5; 6, 3; 12, 6; 27 À-Á 5. 0 0. 45 1000+/-150 12. 6+1. 3/-5. 3 35 2 sealed-contact reed relays of ÌÊÊÀ-27101 of 44õ20õ22
14 RES 82/5
RES 82/5
ÐÑ4. 569. 791-05 4; 5; 6, 3; 12, 6; 27 À-Á 9. 0 0. 8 2460+/-369 27 +/-11 35 2 sealed-contact reed relays of ÌÊÀ-27101 of 44õ20õ22
15 RES 83/1
RES 83/1
ÐÑ4. 569. 792 5; 12, 6; 15; 20; 27 À-Á 2. 3 0. 21 210+/-21 5+0. 5/-1. 4 45 4 sealed-contact reed relays of ÌÊÀ-27101 of 44õ20õ26
16 RES 83/2
RES 83/2
ÐÑ4. 569. 792-01 5; 12, 6; 15; 20; 27 À-Á 5. 0 0. 40 800+/-120 12. 6+1. 3/-5. 3 45 4 sealed-contact reed relays of ÌÊÀ-27101 of 44õ20õ26
17 RES 83/3
RES 83/3
ÐÑ4. 569. 792-02 5; 12, 6; 15; 20; 27 À-Á 8. 5 0. 7 2000+/-300 15+/-1. 5 45 4 sealed-contact reed relays of ÌÊÀ-27101 of 44õ20õ26
18 RES 83/4
RES 83/4
ÐÑ4. 569. 792-03 5; 12, 6; 15; 20; 27 À-Á 10. 5 0. 9 2840+/-426 27+3/-11 45 4 sealed-contact reed relays of ÌÊÀ-27101 of 44õ20õ26
19 RES 83/5
RES 83/5
ÐÑ4. 569. 792-04 5; 12, 6; 15; 20; 27 À-Á 10. 5 0. 85 1900+/-285 27+3/-11 45 4 sealed-contact reed relays of ÌÊÀ-27101 of 44õ20õ26
20 RES 84/1
RES 84/1
ÐÑ4. 569. 793 5; 12, 6; 27; 36 À-Á 2. 2 0. 13 150+/-15 5+0. 5/-1. 4 55 6 sealed-contact reed relays of ÌÊÀ-27101 of 44õ24õ26
21 RES 84/2
RES 84/2
ÐÑ4. 569. 793-01 5; 12, 6; 27; 36 À-Á 5. 0 0. 3 650+/-65 12, 6+1. 3/-5. 3 55 6 sealed-contact reed relays of ÌÊÀ-27101 of 44õ24õ26
22 RES 84/3
RES 84/3
ÐÑ4. 569. 793-02 5; 12, 6; 27; 36 À-Á 10. 5 0. 56 2300+/-345 27+3/-11 55 6 sealed-contact reed relays of ÌÊÀ-27101 of 44õ24õ26
23 RES 84/4
RES 84/4
ÐÑ4. 569. 793-03 5; 12, 6; 27; 36 À-Á 18. 0 1. 1 1500+/-230 36+/-4 55 6 sealed-contact reed relays of ÌÊÀ-27101
24 RES 84/5
RES 84/5
ÐÑ4. 569. 793-03 5; 12, 6; 27; 36 Â-Ã 21. 5 1. 3 5400+/-900 36+/-4 55 6 sealed-contact reed relays of ÌÊÀ-27101