Code Page utf-8
Sistema federale di informazione su merci e servizi
FISinter

Подсистема «Информация производителей продукции»

Scelta della lingua
Ricerca d'informazione
Disposizione d'informazione
Dettagli
Настройки браузера
Архив

Sistemi antincendio e sicurezza, attrezzatura, impianti d'al

aparecchio di ricezione e controllo Agat

 
Paese: Russia
 
 Tipo di fornitore: Produttore  
 Informazioni di fornitore  Codice d'identificazione di produzione

Schiaramento/annotazione:

For centralized and autonomous protection of object of national economy and personal property of citizens from penetration of unauthorized persons and fire.

Descrizione del marchio dettagliata:

The device keeps the capacity to work in case of ambient air temperature from - 30 to +45 degree. With, excess of moisture to 98% at a temperature of 25 degree. S. the device is intended the joint work with ïóëüòàìè centralized observation (ÏÖÍ) type "the centre - the km", "the centre - m", "the Neva - 10 ", "Neva - 10Ì", "the lilac - 24". In signalling plumes could be included in: 1) signalling apparatuses ìàãíèòîêîíòàêòíûå ÑÌÊ-1 type, ÑÌÊ-3; 2) type informers "foil", "of window"; 3) onoff exits of type informers "vector - 3", "echo - 2"; 4) informers fire type "of IP 104 - 1", "flame-ionization detector - 2", "flame-ionization detector - 3"; 5) informers fire heat ìàãíèòîíîêîíòàêòíûå type "of IP 105-2-1".
main technical details and characteristic:
1. 1. Supply voltage: main, V.. 220 +/- 22/23;
voltage of back-up power supply, V. 24 +/-3;
power frequency, Hz. 50 +/-1;
power consumption, VA, not more. 8;
overall dimensions, MM. 170õ160õ80;
mass, kg. 1, 8;
plumes number of signalling, controlled
device. 2;
the size of dc voltage on open-loop
Øëåéôå is on some interval, V.. Of 18 to 27;
1. 2. The device provides:
purposes commutation of ÏÖÍ, the switching current shall not
exceed 50 mitotic activities on tension, in, not more. 120;
circuit switching of nuclear industrial heating plant of 2nd of plume, switched
the direct current should not exceed 100 mitotic activities in case of
voltage, in, not more. 60;
food of active informers with individual exit
voltage 12+3 in case of consumption current, mitotic activity, not more. 100.
1. 3. The device provides the food on ØÑ and the joint work with protective
type informers of io 303-1 "window" in quantitative. 10 states;
fire detectors of ÄÈÏ-3 type in quantitative. 6 states;
1. 4. The device provides the control ØÑ with parameters:
circuit resistance of ØÑ, not more. 1 lump;
resistance between ØÑ leads or between each
by cable and land, no less than. 20 lump.
1. 5. The device issues the alarm notification in case of break or short circuit ØÑ for the time being 70 incineration facilities and more than and is not ejecting alarm notification in case of those and violation conditions of signalling plume for the time being 50 incineration facilities and under.

Condizzioni di fornamento:

Prezzo: pattuito per itm