Bauteile und komplettierende Erzeugnisse der Elektronik

Quarzresonator _________ RKTV206

 
Das Land: Russia
 
 Der Lieferantentyp: Warenhersteller  
 Die Information über den Lieferanten  ProduktionsIdentifizierer

Die Erklärung/Inhaltsangabe:

High-temperature. To the operation in the composition of electronic thermometers and those ðìîðåãóëÿòîðîâ as a transducer running values of òåìï-ðû in frequency. Body clearances: diameter 2ìì, length 6 MM.

Die ausführliche Beschreibung der Marke:

Nominal frequency of Fn. From 32000 to 36000 Hz; tuning accuracy of dF/Fí. +/- 150 ððì; dynamic resistance of Rê. 75 lumps; static capacitance of Ñ0. 1, 3 +/- 0, 2 pension funds; capacitance coefficient of Ñ0/Ñ1. 900 +/- 00; capacity, scattering on resonator of W. 3 microWatts; resonator ageing for first year of storage of dF/Fí. +/- 5 ððì; time constant of thermal inertia in fluid t. 5 secs; temperature-frequency characteristic (Ò×Õ): FT = F0 + A1 ( T-T0) + A2 (T-T0) ^2 + A3 (T-T0) ^3, where: FT - resonator frequency (Hz) in case of running value of temperature t (ãðàäÑ); F0 - resonator frequency (Hz) in case of base significance t temperature (ãðàäÑ); Ò0 - basic value of temperature. to get great accuracy possibly Ò×Õ presentation polunomial "third" degree and factor determination third of procedure: FT = F0 + A1 (T-T0) + A2 (T-T0) ^2 + À3 (Ò-Ò0) ^3 linear coefficient (Ò0=0) À1*. - 1, 811+/-0, 06 Ñ^-1 hail coefficient of second order (Ò0=0) À2*. - 0, 0028+/-0, 0001ãðàäÑ^-2; coefficient of third order (Ò0=0) À3*. 7, 6 kh 10-6 ãðàäÑ^-3; *Ïðèìå÷àíèå - À1 coefficients, À2 and À3 in case of order can be changed; for thermosensitive high-temperature resonators ÐÊÒÂ206 (A.. Ñ) can be supporting thermostabilic quartz the resonator of ÐÊÎÂ206 is selected. temperature limit of capacity to work. From - 269 ãðàäÑ to +125 ãðàäÑ vibration proofness on some interval of 10 to 2000 Hz (acceleration 10g during 8 o'clock). +/- 5 ððì; tolerance for oneshot hits with acceleration from 0 to 5000g in case of duration 0, 2 ms.. +/- 5 ððì; the resonators are products unrestorable and repair not are subject to. The maker guarantees the adequacy in quality of resonator in case of observance by the conditions consumer of transportation, storage and operation. Guarantee period - 50000 ch from the day of input resonators in operation. Guarantee storage life - ten years with time of manufacture. Maximal relative frequency variation resonator for operating time not more +/- 20 ððì. maximal relative frequency variation for guarantee period storage not more +/- 20 ððì. on the basis of òåðìîðåçîíàòîðîâ of ÐÊÒÂ206 and ÐÊÎÂ206 has been developed and the digital clinical thermometer, electronic digital and the analog regulators and thermometers of industrial appointment (from - 50 to 100 ãðàäÑ) quality class to

Die Bedingung der Lieferung:

Der Preis: 05.07.2001 itm Der Großhandelspreis: 1.50 USD(USD)
Der Detailpreis: 2.00 USD(USD)

Prepayment. Ñàìîâûâîç or delivery by parcels. The VAT product are not subjected. Prices with internal undoped hydrogenated amorphous silicon and terms of delivery. Price for resonator also depending t from accuracy of its adjustment.