FISinter (to initial point)
Code Page utf-8
Federative information system of producers on products and services
FISinter

Подсистема «Информация производителей продукции»

Select Language
Information Search
Information Allocation
Details
Настройки браузера
Архив

Measuring instruments and gaging equipment

Water flowmeter turbine VMG


This brand has modifications - select them below after reading annotation and detailed description

Explanation/Annotation:

Iron. For measurement of volume of hot water. Ðó-1, 6 MPa, t- +50/+150 degree. S. Ìåæïðîâåðî÷íûé interval - 4 years.

  Detailed modification description
NNModification marking
Inter
Nat.
Diameter, MM water expenditure: least Gmin, Cuba. ì/÷ transition Gf, Cuba. ì/÷ nominal Gn, Cuba. ì/÷ greatest Gmax, Cuba. ì/÷ threshold of sensitivity, Cuba. ì/÷ construction length, MM weight, kg
1 50
50
50 0. 6 1. 8 15 60 0. 25 200 8. 5
2 65
65
65 1. 0 2. 0 25 90 0. 30 200 11
3 80
80
80 1. 4 3. 2 45 140 0. 35 225 15
4 100
100
100 2. 0 4. 8 70 200 0. 60 250 19
5 150
150
150 4. 5 12. 0 150 500 1. 70 300 36
6 200
200
200 8. 0 20. 0 350 700 4. 0 350 50