Check-out and adjusting instrumentation, transducers

Sensor-relay temperature T419-2M


This brand has modifications - select them below after reading annotation and detailed description

Explanation/Annotation:

Electronic. For two-position temperature control in movable And fixed devices of refrigerating engineering, heatings and ventilations. Can be used as of signalling apparatuses and heat shield appliances.

Detailed model description:

The command outlet of appliances ýëåêòðîêîíòàêòíûé-îäíà switching the plurality. Has the visual indication of inclusion output command chain. As of temperature sensors can be used copper thermoelectric transducers of ÒÑÌ with nominal static characteristic 50Ì (50Îì in case of 0°Ñ) or the platinum thermoelectric transducers of ÒÑÏ with nominal static characteristic 100Ï (100 ohms in case of 0°Ñ). The copper thermoelectric transducers depending on order can or be supplied, or to be not to supplied with appliance; the platinum thermoelectric transducers with appliance is not supplied. Remoteness, metal - 300 (communication line from the sensor - tripple-wire screened, with resistance of every wire 5 ohms). Housing protection - IP44. Return zone controlled in ranges from 1 up to 10°Ñ. With the help of switch at the front of appliance in operation may be transferred in either of the two conditions of: And - with short-circuit make contact in case of temperature rise; B - with short-circuit make contact in case of decrease of temperature. Appliances arrangments on operating supply voltage: 1 - 110Â, 50 (60) Hz; 2 - 220Â, 50 (60) Hz; 3 - (12-24) in direct current; 4 - (45-75) in direct current. Arrangments of Ò419-2Ì-22. 24 are supplied only on supply voltage 220Â, 50 (60) Hz. Switches by contacts the inductive electrical load of alternating current in case of cosª0, 6: On tension of 12 up to 250 - from 0, 1 up to 2, 5À; On tension more than 250 up to 380 - from 0, 1 up to 1, 5À; Resistive load:On tension of 12 up to 250 - from 0, 1 up to 6À. The switching of resistive load up to 10À on tension of 12 is allowed Up to 240Â, frequency of switching not more than 30 cycles per hour and time of continuous current flow through contacts not more than 15ñ in every cycle. Power consumed: for appliances with ac supply - 3 ·À; for appliances with feeding from direct current sources - 2, 5Âò. Mass without sensor, kg - 0, 55. Overall dimensions, mm - 105õ130õ60. Is approved by the register of shipping of navigation. Are replaced Ò419-1Ì.

  Detailed modification description
NNModification marking
Inter
Nat.
Temperature range, °ÑBasic error, °ÑSensor model
1 T419-2M-16
T419-2M-16
200. 300+2100Ï
2 T419-2M-15
T419-2M-15
150. 250+2100Ï
3 T419-2M-14
T419-2M-14
100. 200+2100Ï
4 T419-2M-13
T419-2M-13
200. 250+1100Ï
5 T419-2M-12
T419-2M-12
175. 225+1100Ï
6 T419-2M-11
T419-2M-11
150. 200+1100Ï
7 T419-2M-10
T419-2M-10
50. 150+250Ì
8 T419-2M-09
T419-2M-09
0. 100+250Ì
9 T419-2M-08
T419-2M-08
125. 175+150Ì
10 T419-2M-07
T419-2M-07
100. 150+150Ì
11 T419-2M-05
T419-2M-05
50. 100+150Ì
12 T419-2M-04
T419-2M-04
25. 75+150Ì
13 T419-2M-03
T419-2M-03
0. 50+150Ì
14 T419-2M-02
T419-2M-02
- 25. 25+150Ì
15 T419-2M-01
T419-2M-01
- 50. 0+150Ì
16 T419-2M-17
T419-2M-17
250. 350+2100Ï
17 T419-2M-18
T419-2M-18
300. 400+2100Ï
18 T419-2M-19
T419-2M-19
350. 450+2100Ï
19 T419-2M-20
T419-2M-20
400. 500+2100Ï
20 T419-2M-21
T419-2M-21
- 50. 50+250Ì
21 T419-2M-22
T419-2M-22
0. 100+2100Ï
22 T419-2M-23
T419-2M-23
25. 125+2100Ï
23 T419-2M-24
T419-2M-24
50. 250+4100Ï
24 T419-2M-06
T419-2M-06
75. 125+150Ì