FISinter (to initial point)
Code Page utf-8
Federative information system of producers on products and services
FISinter

Подсистема «Информация производителей продукции»

Select Language
Information Search
Information Allocation
Details
Настройки браузера
Архив

Check-out and adjusting instrumentation, transducers

Sensor-relay temperature TAD101


This brand has modifications - select them below after reading annotation and detailed description

Explanation/Annotation:

Dilatometric. For maintaining of predetermined temperature controlled Environments (non-aggressive to brass and steel). With information scale or Áåñøêàëüíûå. In liquid media is used only with insulation jacket.

Detailed model description:

Are supplied by tuned to specified the setting from number of: 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90. The setting corresponds to contact breaking. The return zone - non-controlled and point in directions of decrease of temperature of controlled medium (relating to settings). Switches the AC circuits with frequency 50 (60) Hz by the stress up to 250Â, strength of current up to 16À, load active. Degree of protection of housing - IP00. Mass, kg, not more than - 0, 085. Overall dimensions (without sensitive element), mm - 30õ34õ31. Is supplied optional with insulation jacket or without it.

  Detailed modification description
NNModification marking
Inter
Nat.
Settings limits, °ÑZone of âîîçâðàòà °ÑOperation dispersion, °Ñ, not more thanLength of sensitive element, mm
1 TAD101-1
TAD101-1
10-90Not more than 112179
2 TAD101-2
TAD101-2
30-90Not more than 92281
3 TAD101-3
TAD101-3
50-80Not more than 72458
4 TAD101-4
TAD101-4
10-9010-204120