Explanation/Annotation:Electronic. For the transformation of temperature in standard output direct current signal 4-20 microampere, used in automatic data acquisition systems, control and regulation.
Detailed model description:Comprises the thermoelectric resistive transducer of ÒÑÌ with nominal static characteristic 50Ì (primary) and the rationing converter (secondary). Has the joined two-wire line of plugging of load and supply voltage.
Limits of measured temperatures, °Ñ: - 50. 150
0. 150
0. 100
- 50. 50
Basic error, %:, - 0, 5
Load impedance, lump: 0-1, 62
Stress of d. c. power supply, in: 9, 6. 42
Power consumed, not more than, watt: 1, 0
Working pressure, MPa: 6, 3
Ambient-air temperature, °Ñ: - 10. 50
Length of protection armature of appliance, mm: exterior - 80;
The submerged ÷àñòè-160, 250, 320 (is mentioned in case of order).
Head overall dimensions of appliance, mm: ô48õ125
Mass, not more than, kg: 0, 5
Housing protection: IP65 |