Sistema federal de información sobre mercancías y servicios (al inicio)
Code Page utf-8
Sistema federativo sobre mercancías y servicios
FISinter

Подсистема «Информация производителей продукции»

Selección de idioma
Búsqueda de información
Ubicación de la información
Detalles
Настройки браузера
Архив

Equipo de ventilación y calefacción

Calentador de agua eléctrico de agua corriente "Ermak"


Para esta marca hay versiones - escójalas abajo después de familiarizarse con el resumen y descripció detallada

Aclaración/resumen:

For room heating by the area of 30 to 600 apartment of M..

Descripción completa de la marca:

For the first time in Russia in heating technology microprocessor-based the control block, which is applied: 1. The microprocessor provides the boiler work in automated fashion; 2. Supports baseline electrical power; 3. The connecting of room thermostat permit maintaining desired the temperature of indoor air with precision the plus or minus 10 degree. With; 4. The non-volatile memory provides the preservation of specified parameters; 5. The control circuit allows to avoid commissioning voltage jumps in network and electro-magnetic interferences; 6. Sparing the condition to the operation of heaters sets up the most, that increases their durality; 7. Allows to break the boiler capacity by 10 stages with step by 10% from rated horsepower (10%, 100%), what makes it possible more than flexibly to select the boiler capacity on consumer desire; 8. In "onoff condition" operates 3th by the capacity stages: 40%, 60% and 100% rated horsepower. 9. The capacity at the same time on 3 phases on set by heat-transfer agents temperature within a range of chosen stage by degrees regulates, that excludes the over-extension possibility in electrical network; 10. Saves at the expense of all just listed items to 20% electric power. total technical characteristics: business hour. Long-term frequency, Hz. 50 maximal of t of heat-carrying agent, growth hormone GH. S. 90 accidental ñðàáàòûâàåíèå in case of t of heat-carrying agent, growth hormone GH. S. 95 task discreteness t, growth hormone GH. S. 1 allowable pressure, MPa. 0, 3 boiler material. Stainless steel class of protection. 1 degree of protection. Áðûçãîçàùèòíîå execution of IP24

  Versiones/????????????
No.Marcación de la versión
Inter
Nac.
The power-control band, kilowatt heated the area, ì2 the maximal current, and the network voltage, in the Baku volume, äì3 the diameter of conjuctive branch pipes, Äó/òðóáí. | mass, kg, not more height, MM length, MM width, MM
1 03
03
0-3 30 14 220 8 20/ 3/4 "14 510 300 200
2 06
06
0-6 60 9 380 9 25/1 "16 510 330 230
3 09
09
0-9 90 14 380 11 25/1 "20 510 380 240
4 12
12
0-12 120 19 380 11 25/1 "20 510 380 240
5 15
15
0-15 150 23 380 11 25/1 "20 510 380 240
6 24
24
0-24 240 38 380 15 25/1 "26 730 380 240