L'explication/l'anotation:Braking signal. MM analogue 125Ä. For turning on and off of signal device in case of downfall or raising of brake pressure of KAMAZ car.
La description détaillée de marque:The operation limits from 0, 05 MPa to 0, 01 MPa (from 0, 5 to 0, 1 kg ñì^2) at a temperature of - 60 S. to +80 S.
is designed to be operated in single-wire DC circuit: voltage 12 in, amperage 0, 4 and; íàïð÷æåíèå 24 in, amperage 0, 25 A.
the probe has to withstand the overload pressure to 2, 5 + 0, 5 MPa (25 + 5 kgs ñì^2 without appearing of mechanical damages, depressurization. The probe is to survive in case of reduction of atmosphere pressure to 61000 p (460 MM Hg column. , that corresponds pressure at altitude 4000 m above sea level. |