Code Page utf-8
Système fédérative d'information sur des biens et services
FISinter

Подсистема «Информация производителей продукции»

Le choix de langue
La recherche d'information
Le placement d'information
Les détails
Настройки браузера
Архив

L'outillage et l'équipement radioélectronique

Compteur d'électricité SEB-2

 
Le pays: Russie
 
 le type du fournisseur: le producteur  
 L'information sur le fournisseur  Indicateurs des produits

L'explication/l'anotation:

Household counter of electrical energy - monophase, direct inclusions, äâóõòàðèôíûé. To accommodate active energy in two-wire ts drinks of alternate current by the frequency 50Ãö.

La description détaillée de marque:

The counter may to work in conventional or computer-based system due information on expenditure of electrical energy on two rates. Ëãîòíûé the payment rate is established in time dependence of days and days íå- Delhi. It may be differentiated from standard rate several time (for example in Nizhegorodskaya region in 4ðàçà). the payment shall be performed in accordance with indications for every two counting devices of counter. Statement are read by visually or òå- ëåìåòðè÷åñêè. | ÑÝÁ-2 is different from similar induction meters ðàñøèðåí- Noy range accounted bear loads (1. 1000 % rated control current), øè- ðîêèì temperature range, telemetric impulse exit, in çìîæíîñòüþ of ïîòàðèôíîãî remote switching of counting devices the counter is accomplished to modern hardware using two ñóïåðáîëüøèõ integrated circuits. VLSI exercise functions ïðåîáðàçî- âàíèÿ and measurement of power, as well as conjugation with reading óñòðîé- hyperfine interactions, as a which are used 2 stepped mechanisms. main technical characteristics. quality class. 2 maximal amperage. 50 and nominal amperage. 5 and nominal voltage. 220 in parameters of actuating signal: voltage. 187. 242 in amperage. 0, 023. 50 and threshold of sensitivity. 5 computer engineerings frequency range of measuring circuit of counter. 47. 63 Hz full of power consumption. Not more 1, 5 VA gear ratio of impulse exits: main transmission device. 500 èìï/êÂò hour test exit. 64000 èìï/êÂò hour short-time overloads by the input current. 150 and overall dimensions. 65õ140õ218 of MM mass. Not more 0, 8 kg mean time between failures. 35000 hours average life. No less than 30 years recalibration interval. No less than 6 years operation condition: ambient air temperature. - 40. +55 hail with relative humidity at a temperature of 25 hails S.. Not more 98 %

Les conditions de fourniture:

Le prix; de contrat pour itm