Impianti e materiali di controllo e di regolazione

trasduttore-rele di temperatura TAM123


Per questo marchio ci sono delle modificazioni - sceglietele quм di sotto dopo aver preso conoscenza di annotazione con descrizione dettagliato

Schiaramento/annotazione:

Manometric. For controlling and control of temperature of liquid and gas mediums in cooling, freezing, ventilation and heating installations.

Descrizione del marchio dettagliata:

Combined limits of settings, °Ñ (34 modifications) - from - 35 up to 130 Return zone, controlled or non-controlled (depending on modification), °Ñ - from 3, 5 up to 10 Remoteness, (depending on modification), metal - 2; 4, 6 Overall dimensions on chassis earth mm - 84õ67õ49 Mass, kg, not more than - 0, 5 kg Housing protection - IÐ33. Within limits of settings can be supplied with fixed by settings with tuning accuracy +1, 5 °Ñ. Maximal temperature of controlled medium - from 70 up to 145 °Ñ (depending on modification). Environment temperature - from - 40 up to 70 °Ñ. Switching current - 0, 05-16 and on tension up to 380 in frequency 50 (60) Hz. Switching power on tension up to 220 in direct current - 12 watts. Controlled mediums: air, refigerants, oils, diesel fuel, water and other, non-aggressive to copper and copper alloys.

  Modificazioni
numero d'ordineMarchiatura della modificazione
Inter
Nazionale
Limits of controlled settingsFixed the setting, within limitsReturn zone, controlledReturn zone, non adjustable (not more than)Return zone, fixedMaximal temperature of controlled mediumZone direction of return relating to setting
1 TAM123-01-1.1
TAM123-01-1.1
From - 30 up to - 5-From 4 up to 10--120On increase
2 TAM123-01-1.0
TAM123-01-1.0
From - 30 up to - 5--3, 5-120On increase
3 TAM123-01-2.0
TAM123-01-2.0
From - 30 up to - 5--3, 5-120On lowering
4 TAM123-10-1.0
TAM123-10-1.0
-From - 30 up to - 5-3, 5-120On increase
5 TAM123-10-2.0
TAM123-10-2.0
-From - 30 up to - 5-3, 5-120On lowering
6 TAM123-10-1.2
TAM123-10-1.2
-From - 30 up to - 5--From 4 up to 10120On increase
7 TAM123-02-1.1
TAM123-02-1.1
From - 20 up to 10-From 4 up to 10--120On increase
8 TAM123-02-1.0
TAM123-02-1.0
From - 20 up to 10--3, 5-120On increase
9 TAM123-02-2.0
TAM123-02-2.0
From - 20 up to 10--3, 5-120On lowering
10 TAM123-20-
TAM123-20-
-From - 20 up to 10-3, 5-120On increase
11 TAM123-20-2.0
TAM123-20-2.0
-From - 20 up to 10-3, 5-120On lowering
12 TAM123-20-1.2
TAM123-20-1.2
-From - 20 up to 10--From 4 up to 10120On increase
13 TAM123-03-1.1
TAM123-03-1.1
From 5 up to 35-From 4 up to 10--70On increase
14 TAM123-03-1.0
TAM123-03-1.0
From 5 up to 35--3, 5-70On increase
15 TAM123-03-2.0
TAM123-03-2.0
From 5 up to 35--3, 5-70On lowering
16 TAM123-30-1.0
TAM123-30-1.0
-From 5 up to 35-3, 5-70On increase
17 TAM123-30-2.0
TAM123-30-2.0
-From 5 up to 35-3, 5-70On lowering
18 TAM123-30-1.2
TAM123-30-1.2
-From 5 up to 35--From 4 up to 1070On increase
19 TAM123-04-1.1
TAM123-04-1.1
Of 30 up to 60-From 4 up to 10--80On increase
20 TAM123-04-1.0
TAM123-04-1.0
Of 30 up to 60--3, 5-80On increase
21 TAM123-04-2.0
TAM123-04-2.0
Of 30 up to 60--3, 5-80On lowering
22 TAM123-40-1.0
TAM123-40-1.0
-Of 30 up to 60-3, 5-80On increase
23 TAM123-40-2.0
TAM123-40-2.0
-Of 30 up to 60-3, 5-80On lowering
24 TAM123-40-1.2
TAM123-40-1.2
-Of 30 up to 60--From 4 up to 1080On increase
25 TAM123-05-1.0
TAM123-05-1.0
From 50 up to 130--8-145On increase
26 TAM 123-05-2.0
TAM 123-05-2.0
From 50 up to 130--8-145On lowering
27 TAM123-50-1.0